LC4H-S
Setting the operation mode and counter
Setting procedure 1) Setting the operation mode (input mode and output mode)
Set the input and output modes with the DIP switches on the side of the counter.
DIP switches
Table 1: Setting the output mode
Item
DIP switch
OFF ON
1
DIP switch No.
2
3
Output mode
1
ON ON ON
SHOT-A
2
3
Output mode
Refer to table 1
OFF OFF OFF
ON OFF OFF
SHOT-B
SHOT-C
4
5
Minimum reset input signal width
Maximum counter setting
20 ms
30 Hz
1 ms
5 kHz
OFF ON OFF
ON ON OFF
SHOT-D
HOLD-A
6
OFF OFF ON
HOLD-B
7
8
Input mode
Refer to table 2
ON OFF ON
OFF ON ON
HOLD-C
— (See note 1)
Table 2: Setting the input mode
DIP switches (See note 2)
6
DIP switch No.
7
8
Input mode
1
2
3
4
5
6
7
8
ON ON ON Addition input
OFF OFF OFF Subtraction input
ON OFF OFF Directive input
OFF ON OFF Independent input
ON ON OFF Phase input
(Same for 6-digit, screw-down terminal type)
OFF OFF ON — (See note 1)
ON OFF ON — (See note 1)
OFF ON ON — (See note 1)
Notes:1) The counter and set value displays will display DIP Err.
Notes: 2) Set the DIP switches before installing the counter on the panel.
Notes: 3) When the DIP SW setting is changed, turn off the power once.
Notes: 4) The DIP switches are set as ON before shipping.
Setting procedure 2) Setting the set value
Set the set value with the UP and DOWN keys on the front of the counter.
Front display section
? 4-digit display type
U DOWN keys
Q Counter display
W Set value display
COUNTER
1
Changes the corresponding digit of the set
value in the subtraction direction (down-
E Controlled output indicator
3
2
wards)
R Reset indicator
T Lock indicator
Y UP keys
Changes the corresponding
digit of the set value in the
4
5
8
9
OP.
RST
LOCK
RESET
SET/LOCK
LC4H
UP
DOWN
6
7
I RESET switch
Resets the counting value and the output
O SET/LOCK switch
This is used to handle pre-scaling values,
one-shot times, decimal point position set-
addition direction (upwards)
? 6-digit display type
tings, and key lock operations (to disable Up
key, Down key, and Reset key operations).
Y UP keys
Q Counter display
W Set value display
E Controlled output indicator
R Reset indicator
T Lock indicator
3
4
5
7
OP.
RST
LOCK
RESET
SET/LOCK
COUNTER
1
2
6
Changes the corresponding digit of the set
value in the addition direction (upwards)
U RESET switch
Resets the counting value and the output
I SET/LOCK switch
This is used to handle pre-scaling values,
8
LC4H
one-shot times, decimal point position set-
tings, and key lock operations (to disable Up
key, Down key, and Reset key operations).
Setting procedure 3) Setting the input mode
The input mode is set using the key switch in the [Display] section on the front of the counter.
? Decimal point position setting mode
Q Holding down the [SET/LOCK] key, press the key for the second digit to access the decimal point position setting mode.
Example) 6-digit type
Decimal point position setting mode display
(Example shows default value displayed)
W When the setting mode has been accessed, release the [SET/LOCK] key.
All Rights Reserved ? C OPYRIGHT Matsushita Electric Works, Ltd.
相关PDF资料
P51-500-A-O-P-5V-000-000 SENSOR 500PSI 7/16-20 UNF 2B 5V
P51-300-A-O-P-5V-000-000 SENSOR 300PSI 7/16-20 UNF 2B 5V
P51-200-A-O-P-5V-000-000 SENSOR 200PSI 7/16-20 UNF 2B 5V
P51-100-A-O-P-5V-000-000 SENSOR 100PSI 7/16-20 UNF 2B 5V
P51-75-A-O-P-5V-000-000 SENSOR 75PSI 7/16-20 UNF 2B 5V
11-01-0101 TOOL HAND CRIMP 14-20AWG
555-5403F LED CBI 2MM YLW 5V RES QUAD TH
ASFLMPC-25.000MHZ-Z-T OSC 25.000 MHZ CMOS MEMS SMD
相关代理商/技术参数
LC4HR4DC24VS 制造商:OMRON 功能描述:*
LC4H-R4-DC24VS 功能描述:计数器和转速计 24VDC SCREW TERM RoHS:否 制造商:Honeywell 显示器类型: 准确性:0.5 系列:SNDJ-CNT
LC4HR6240ACS 制造商:Panasonic Electric Works 功能描述:COUNTER LC4HR6-240VACS
LC4HR6240ACSJ 制造商:Panasonic Industrial Company 功能描述:
LC4HR624DCS 制造商:Panasonic Electric Works 功能描述:COUNTER LC4HR6-24VDCS
LC4HR624SJ 制造商:Panasonic Industrial Company 功能描述:
LC4H-R6-AC240V 制造商:Panasonic Electric Works 功能描述:Din 48 Size LCD Electronic Counter
LC4H-R6-AC240VS 功能描述:计数器和转速计 DIGITAL COUNTER SCREW 64.5MM 24VDC RoHS:否 制造商:Honeywell 显示器类型: 准确性:0.5 系列:SNDJ-CNT